ALLIANCE AVIV: Safety and Effectiveness of the SAPIEN X4 Transcatheter Heart Valve in Failing Aortic Bioprosthetic Valves

Brief Summary
The objective of this study is to establish the safety and effectiveness of the Edwards SAPIEN X4 Transcatheter Heart Valve (THV) in subjects who are at high or greater risk with a failing aortic bioprosthetic valve.
Brief Title
ALLIANCE AVIV: Safety and Effectiveness of the SAPIEN X4 Transcatheter Heart Valve in Failing Aortic Bioprosthetic Valves
Detailed Description
Prospective, single arm, multicenter study
Central Contacts
Central Contact Role
Contact
Central Contact Phone
949-250-2500
Central Contact Email
THV_CT.gov@Edwards.com
Completion Date
Completion Date Type
Estimated
Conditions
Aortic Valve Insufficiency
Aortic Valve Stenosis
Eligibility Criteria
Inclusion Criteria:

1. Failing aortic bioprosthetic valve demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency
2. Bioprosthetic valve size suitable for SAPIEN X4 THV
3. NYHA functional class ≥ II
4. Heart Team agrees the subject is at high or greater surgical risk
5. The subject has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.

Exclusion Criteria:

1. Anatomical characteristics that would preclude safe femoral placement of the introducer sheath or safe passage of the delivery system
2. Failing valve has moderate or severe paravalvular regurgitation
3. Failing valve is unstable, rocking, or not structurally intact
4. Known severe patient-prosthesis mismatch or bioprosthetic valve with residual mean gradient \> 20 mmHg at the end of the index procedure for implantation of the original valve
5. Increased risk of THV embolization
6. Surgical or transcatheter valve in the mitral position
7. Severe mitral regurgitation (\> 3+) or ≥ moderate mitral stenosis
8. Need for mitral, tricuspid or pulmonic valve intervention within the next 12 months
9. Left ventricular ejection fraction \< 20%
10. Cardiac imaging evidence of intracardiac mass, thrombus or vegetation
11. Increased risk of coronary artery obstruction after THV implantation
12. Myocardial infarction within 30 days prior to the study procedure
13. Hypertrophic cardiomyopathy with subvalvular obstruction
14. Subjects with planned concomitant ablation for atrial fibrillation
15. Clinically significant coronary artery disease requiring revascularization
16. Any surgical or transcatheter procedure within 30 days prior to the study procedure. Implantation of a permanent pacemaker or implantable cardioverter defibrillator is not considered an exclusion.
17. Any planned surgical or transcatheter intervention to be performed within 30 days following the study procedure
18. Endocarditis within 180 days prior to the study procedure
19. Stroke, transient ischemic attack or neurological signs and symptoms attributed to carotid or vertebrobasilar disease within 90 days prior to the study procedure
20. Hemodynamic or respiratory instability requiring inotropic or mechanical support within 30 days prior to the study procedure
21. Renal insufficiency and/or renal replacement therapy
22. Leukopenia, anemia, thrombocytopenia
23. Inability to tolerate or condition precluding treatment with antithrombotic therapy
24. Hypercoagulable state or other condition that increases risk of thrombosis
25. Absolute contraindications or allergy to iodinated contrast that cannot be adequately treated with premedication
26. Subject refuses blood products
27. Body mass index \> 50 kg/m2
28. Estimated life expectancy \< 24 months
29. Female who is pregnant or lactating
30. Active SARS-CoV-2 infection or previously diagnosed with COVID-19 with sequelae that could confound endpoint assessments
31. Participating in another investigational drug or device study that has not reached its primary endpoint
32. Subject considered to be part of a vulnerable population
Inclusion Criteria
Inclusion Criteria:

1. Failing aortic bioprosthetic valve demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency
2. Bioprosthetic valve size suitable for SAPIEN X4 THV
3. NYHA functional class ≥ II
4. Heart Team agrees the subject is at high or greater surgical risk
5. The subject has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.

Gender
All
Gender Based
false
Keywords
Transcatheter aortic valve replacement (TAVR)
Transcatheter aortic valve implantation (TAVI)
SAPIEN X4
Valve-in-valve
Healthy Volunteers
No
Last Update Submit Date
NCT Id
NCT05172973
Org Class
Industry
Org Full Name
Edwards Lifesciences
Org Study Id
2021-05-AVIV
Overall Status
Recruiting
Phases
Not Applicable
Primary Completion Date
Primary Completion Date Type
Estimated
Official Title
Safety and Effectiveness of Balloon-Expandable Bioprosthetic SAPIEN X4 Transcatheter Heart Valve in Failing Aortic Bioprosthetic Valves
Primary Outcomes
Outcome Description
The number of patients that died or had a stroke
Outcome Measure
Non-hierarchical composite of death and stroke
Outcome Time Frame
1 year
Secondary Outcomes
Outcome Description
The KCCQ is a 23-item, self-administered instrument that quantifies physical function, symptoms (frequency, severity and recent change), social function, self-efficacy and knowledge, and quality of life. An overall summary score can be derived from the physical function, symptom (frequency and severity), social function and quality of life domains. Scores are transformed to a range of 0-100, in which higher scores reflect better health status.
Outcome Time Frame
30 days
Outcome Measure
Kansas City Cardiomyopathy Questionnaire (KCCQ) score
Outcome Time Frame
1 year
Outcome Measure
KCCQ score
Outcome Description
NYHA is a functional classification of heart failure based on how much a patient is limited during physical activity. The rating ranges from I - IV, with the lowest (I) as no limitations and the highest (IV) unable to carry on any physical activity without discomfort.
Outcome Time Frame
30 days
Outcome Measure
New York Heart Association (NYHA) functional class
Outcome Time Frame
1 year
Outcome Measure
NYHA functional class
Start Date
Start Date Type
Actual
Status Verified Date
First Submit Date
First Submit QC Date
Std Ages
Child
Adult
Older Adult
Maximum Age Number (converted to Years and rounded down)
999
Minimum Age Number (converted to Years and rounded down)
0
Investigators
Investigator Type
Principal Investigator
Investigator Name
Mohamed Azeem Latib
Investigator Email
mlatib@montefiore.org
Investigator Phone
646-773-2076
Investigator Department
Medicine
Investigator Division
Cardiology
Investigator Sponsor Organization
Montefiore
Study Department
Medicine
Study Division
Cardiology
Categories Mesh Debug
Heart/Cardiovascular --- HEART VALVE DISEASES
Brain, Spinal Cord & Nervous System --- HEART DISEASES
Heart/Cardiovascular --- HEART DISEASES
Blood Disorders --- CARDIOVASCULAR DISEASES
Heart/Cardiovascular --- CARDIOVASCULAR DISEASES
MeSH Terms
AORTIC VALVE INSUFFICIENCY
AORTIC VALVE STENOSIS
AORTIC VALVE DISEASE
HEART VALVE DISEASES
HEART DISEASES
CARDIOVASCULAR DISEASES
VENTRICULAR OUTFLOW OBSTRUCTION